The OCT series adopts the most advanced circuit architecture to enhance inverter stability and incorporates features that best meet end users' needs, addressing all their concerns regarding electricity usage. The OCT series offers unlimited load capacity, peak shaving and valley filling, supports two loads in off-grid mode, and can connect three loads in grid-connected mode—each intelligently managed to maximize power utilization and minimize waste.
| Modle | OCT-U-I-6KW | OCT-U-I-8KW | OCT-U-I-10KW | OCT-U-I-12KW |
| AC Output | ||||
| Rated Power | 6KW/6KVA | 8KW/8KVA | 10KW/10KVA | 12KW/12KVA |
| Surge Power | 12KW/12KVA | 16KW/16KVA | 20KW/20KVA | 24KW/24KVA |
| Parallel 0ption | 9Pcs | |||
| AC Output Voltage | Single Phase:100V/110V/120V/127V Split Phase: 120V/240V 2/3 Phase:127V/220V Parallel Mode Three-Phase:120V/208V | |||
| Rated AC Output Frequency | 50Hz / 60Hz (Auto detection) | |||
| Max Bypass Output Current | 50A | 70A | 70A | 70A |
| AC Output Interface | Load+Smart Load+On grid load | |||
| Max Inverter Efficiency | 96.5%(PV/AC) | |||
| Transfer Time | <20ms@Single,<30ms @ Parallel | |||
| Output Waveform | Pure Sine Wave | |||
| Power Factor | 1 | |||
| No-Load Loss | <75W@Rate Voltage | |||
| AC Output(On Grid) | ||||
| Rated Power | 6KW/6KVA | 8KW/8KVA | 10KW/10KVA | 12KW/12KVA |
| Power Factor | 0.8 leading to 0.8 lagging | |||
| Rated Voltage | Single Phase:120V Split Phase:120V/240V 2/3 Phase:127V/220V Parallel Mode Three-Phase:120V/208V | |||
| Rated Grid Frequency | 60Hz | |||
| Max Output Current | 27A | 35A | 43A | 52A |
| THD | <5% | |||
| PV Input | ||||
| Type Of PV Array Input Terminal | Screw-type terminal block | |||
| Number Of MPPT Trackers | 2 | |||
| Max PV Input Power | 4500W+4500W | 6000W+6000W | 7500W+7500W | 9000W+9000W |
| Max PV Array Open Circuit Voltage | 550Vdc | |||
| Rated Input Voltage Of Photovoltaic System | 380Vdc | |||
| Max PV Input Current / Per String | 27A*2 | |||
| Startup Voltage | 65Vdc | |||
| MPPT Voltage Range | 65~480Vdc | |||
| Battery | ||||
| Compatible Battery Types | Lithium battery, lead-acid battery | |||
| Rated Battery Voltage | 48V | |||
| Battery Voltage Range | 38.4Vdc~60Vdc | |||
| Minimum Cold Start Battery Voltage | 46Vdc | |||
| Battery Overcharge Protection Voltage | 60Vdc | |||
| Max Charging / Discharging Current | 140A | 190A | 220A | 250A |
| Max Charging Power | 6000W | 8000W | 10000W | 12000W |
| MPP tracking efficiency | 99.9% | |||
| Activate The Lithium Battery Function | Yes | |||
| Protection | ||||
| Over Current/ Voltage Protection | Yes | |||
| Anti-islanding Protection | Yes | |||
| AC Short-Circuit Current Protection | Yes | |||
| Leakage Current Protection | Yes | |||
| Ground Fault Monitoring | Yes | |||
| Grid Monitoring | Yes | |||
| DC surge protection Type lll | OVC II | |||
| AC surge protection Type lll | OVC III | |||
| Mechanical Specifications | ||||
| Communication Interface | USB / CAN /RS485/CT | |||
| Monitoring Option | WiFi Module | |||
| Quality Guarantee | 3 years | |||
| Environment | ||||
| Protection Degree | IP20 | |||
| Humidity | 5%~95% non-condensing | |||
| Altitude | <2000 Meters | |||
| 0perating Temperature | -10℃~50℃ | |||
| Storage Temperature | -15℃~60℃ | |||
| Noise | <75db | |||
| Type Of Cooling | Fan | |||
| Certificate | UL 1741、FCC | |||